time:2021-01-18 browse:second
FMVT200 is a vortex flowmeter that is developed and produced by our company, it is a product carefully built on the basis of comprehensively absorbing domestic and foreign advanced technology and years of development and production experience. This product has the features of advanced functions, low power consumption, simple structure, low resistance loss, stable operation, sturdy and durable, wide application, long service life and easy installation and debugging. The intelligentization, standardization, serialization and generalization of products are realized, and the quality and aesthetics of the products are ensured. FMVT200 vortex flowmeter is suitable for flow measurement of liquid and gas media of different calibers, and it's widely applied in the fields of petroleum, chemical industry, urban water supply and drainage, hydrology, etc.
• Advanced circuit design, the circuit board has both micro-power amplifier board and current output function.
• Wide range ratio.
• Output 4mA~20mA DC current signal (2-wire) corresponding to the flow signal.
• Simultaneous display of cumulative flow and instantaneous flow.
• It has five-segment nonlinear correction, small signal cut-off, and free setting of damping time.
• Fully universal design, small overall size and compact structure. Suitable for flow measurement of liquid and gas media of different calibers;
• Advanced user-friendly design, easy to operate.
Measuring Medium | Liquid, gas, steam |
Medium temp. | -40℃~80℃, The highest temperature can reach 280℃ |
Medium pressure | 0MPa~10MPa |
Basic error | Full pipe: ±1.0%; Insertion type: ±1.5% |
Theoretical range ratio | 1:10, 1:20(liquid) |
Flow speed range | Liquid(water): 0.7m/s~7m/s; gas: 5m/s~70m/s; steam: 4m/s~70m/s |
DN(mm) | Full pipe: 15, 25, (32), 45, 50, (65), 80, 100, (125), 150, 200, 250, 300 |
Insertion type: 300~2000(recommended) | |
Reynolds number | Re>4000 |
Resistance coefficient | Full pipe: Cd≤2.4, resistance loss of insertion type could be negligible |
Explosion-proof grade | Intrinsically safe: ExiaⅡT2-T5, Exd: ExdⅡBT4 |
Environment temp. | Non-explosion-proof place: -40℃~55℃, Explosion-proof place: -20℃~55℃ |
Direct power supply | +24V DC local digital display; Battery supply +3.6V, last for 2~3 years |
Output Signal | Frequency pulse signal 1Hz~2600Hz, low level≤1V, high level≥5V, transmitter: 4mA~20mA DC(2-wire) |
Material | 1Cr18Ni9Ti |
Order Guide | ||||||||||
FMVT200 | Vortex Flowmeter | |||||||||
Nominal diameter | -XXX | 050 means DN50; 100means DN100 | ||||||||
Measuring medium | O | Liquid | ||||||||
G | Gas | |||||||||
S | Steam | |||||||||
Structure Type | L | Thread mounting | ||||||||
F | Flange mounting | |||||||||
Fk | Flange clamp-on type | |||||||||
Sp | Simple insertion type | |||||||||
Bp | Ball valve insertion type | |||||||||
Output signal | N | Without output | ||||||||
E | 4mA~20mA DC | |||||||||
M | Pulse | |||||||||
H | HART | |||||||||
R8 | RS485, standard Modbus communication protocol | |||||||||
Compensation | N | Non-compensation | ||||||||
Ct | Temperature compensation only | |||||||||
Cp | Pressure compensation only | |||||||||
Ctp | Temperature and pressure compensation | |||||||||
Converter Type | I | Integrated(Id: with display; Ib: without display) | ||||||||
S | Separated | |||||||||
Temperature | Tc | Common temperature | ||||||||
Th | High temperature | |||||||||
Pressure | Pc | Normal pressure | ||||||||
Ph | High pressure | |||||||||
Working environment | N | General environment | ||||||||
d | Explosion-proof environment | |||||||||
Power supply | V0 | Battery power | ||||||||
V1 | DC 24V(Integrated) | |||||||||
V2 | AC 220V(Separated, with flow totalizer) | |||||||||
V3 | AC 220V(Separated,with heat totalizer) | |||||||||
the whole spec. | Example: FMVT200-100-SFkE-Ctp-Id-TcPc-NV1 |
FMVT200 vortex flowmeter is suitable for flow measurement of liquid and gas media of different calibers, and it's widely applied in the fields of petroleum, chemical industry, urban water supply and drainage, hydrology, etc.