time:2021-01-11 browse:second
LTC4881 liquid level transmitting controller is an intelligent instrument integrating liquid level measurement, display, transmission and control, this product adopts advanced ARM processing chip. while achieving accurate measurement, it can provide rapid response and control of multiple relays by compensation and adjustment of sensor. The controller supports peak record and action delay, display is clear and easy to read. The design of multiple buttons makes the operation easier and more convenient, and the signal output form can be switched between voltage and current. The product provides three installation forms: baseplate, guide rail and panel, protection grade for its body is IP65, and protection grade for the probe is IP68.
LTC4881 liquid level transmitting controller provides 5 relay outputs + 1 analog output, which is widely applied in liquid level detection, action control and water level alarm of petroleum, chemical industry, urban water supply and drainage etc.
● Level measurement for liquid media
● 14-segment LED display
● Button programming, simple operation
● Max. 5 relays control independently, time-delay function
● Switchable analog output form
● Record the highest liquid level during work(can be cleared by key)
● Baseplate, guide rail and panel installation forms optional
● Hardware misoperation protection
● Support MODBUS communication
Input | Power Supply | (220±44)V AC/22V~32V DC |
Range | 1m,2m,5m,10m,20m,50m,100m,200mH₂O | |
Overpressure | 1.5 times FS | |
Output | Accuracy | ≤±0.5%FS |
Repeatability | ≤±0.2%FS | |
Display | 4 digit 0.56 inch 14-segment LED display | |
Display Refresh | 200ms | |
Temperature drift | ≤±0.03%FS/℃ (Zero/FS) | |
Resolution | 0.1cm | |
Analog Output | Current type | 4mA~20mA DC, Load resistance ≤560Ω |
Voltage type | 0V~10V DC, Load resistance ≥10kΩ | |
Switch Output | Output Mode | 5 relays, normally open or closed contact |
Switching voltage | ≤277V AC;≤30V DC | |
Switching current | ≤3A | |
Response time | <1ms | |
Switch Point Setting | 1.5%FS~99%FS | |
Return Difference Setting | 1%FS~10%FS | |
Relay Life | ≥10,000,000 times/load (min.);≥100,000 times/load (max.) | |
Switch Delay | 0s~99s | |
Environmental Conditions | Operation Temp. | -25℃~65℃/-13℉~149℉ |
Storage Temp. | -40℃~70℃/-40℉~158℉ | |
Media Temp. | -20℃~80℃/-50℉~176℉ | |
Relative Humidity | 0%~85% | |
Electromagnetic compatibility | GB/T 17626.2/3/4-2006 | |
Viberation | ≤5g/10Hz...500Hz(IEC 60068-2-6-2007) | |
Impact | ≤10g/11ms(IEC 60068-2-27-2008) | |
Protection | Controller Body IP65;Probe IP68 |
Unit: mm
LTC4881 | Liquid Level Transmitting Controller | |||
Range | Measurement Range: 1, 2, 5, 10, 20, 50, 100, 200mH₂O | |||
[0m~Xm]L | X: Actual measurement range L: Cable length, L-X=(1~2)m suggested | |||
Code | Power Supply | |||
AC | 220V AC | |||
DC | 22V~32V DC | |||
Code | Output Signal | |||
KA | 5-relay+analog(4mA~20mA DC ) | |||
KV | 5-relay+analog(0V~10V DC) | |||
KAV | 5-relay+analog(4mA~20mA/0V~10V DC double use) | |||
LTC4881 | [0m~3m]5 | DC | KA | the whole spec. |
LTC4881 liquid level transmitting controller provides 5 relay outputs + 1 analog output, which is widely applied in liquid level detection, action control and water level alarm of petroleum, chemical industry, urban water supply and drainage etc.